اخبار

Water Cooled Condenser, Shell & Tube Type, Cooling Water Circuit & Water Quality Requirement

  • دسته‌بندی:
  • تعداد بازدید: ...
  • تاریخ انتشار: 2026-10-31

Water Cooled Condenser, Shell & Tube Type, Cooling Water Circuit & Water Quality Requirement

Shell and tube water cooled condenser: high pressure refrigerant gas outside tubes, cooling water flows inside copper tubes for heat exchange. Heat transfer efficiency is higher than air cooled type, stable condensing temperature, suitable for large rack unit and high heat load. Cooling water takes heat away and flows to cooling tower for re-cooling; water system needs water pump, pipeline, water treatment. Water quality control is critical: high hardness water causes scale attached on inner tube wall, heat transfer capacity drops sharply. Xiteliduo shell and tube condenser adopts seamless copper tube, can be matched with open type or closed cooling tower. Water flow rate must keep within design range; insufficient water flow leads to high condensing pressure; excessive flow wastes pump power. Water side chemical cleaning is required periodically; scale, slime and algae are hard to remove once thickened. Winter low ambient region needs water circuit anti-freeze: drain water, add antifreeze or install tracing heating cable. Water cooled system has more auxiliary equipment, higher initial investment and maintenance cost than air cooled solution. Refrigeration maintenance & repair company monitors water inlet/outlet temperature difference to judge fouling degree.

FAQ

  1. What is the mainstream structure of water cooled condenser? Shell and tube type.
  2. Which medium flows inside the tube? Cooling water.
  3. What is the advantage of water cooled condenser? Higher heat exchange efficiency, stable condensing pressure.
  4. What is the main hazard of hard cooling water? Scale formation on inner tube wall.
  5. What equipment is needed to cooperate with water cooled condenser? Cooling tower and water circulation pump.
  6. How to judge water side fouling? Water temperature difference becomes smaller than design value.
  7. What protection for water circuit in cold winter? Drain water, antifreeze liquid or heat tracing.
  8. What is the disadvantage of water cooled system? Extra water system investment and maintenance work.
آدرس: https://fa.xtldcool.com/news/843.html

طرح های سفارشی سازی محصول را به صورت آنلاین دریافت کنید

لطفا شرایط لازم را در کادر زیر پر کنید تا بتوانید آن را به صورت رایگان دریافت کنید.

خط تلفن مشاوره ای

+86-18157593311

شیتلیدو و چوانلی

کارخانه چین، کمپرسور پیستونی نیمه هرمسی R32 و سیستم تبرید صنعتی سفارشی در دست. کمپرسور خودتوسعه یافته + محلول کامل سردکننده، عملکرد پایدار برای شرایط کاری گرمسیری و دمای بسیار پایین.

ما را وصل کنید

خدمات فنی: +86-575-83665888;83068555

خط تلفن کمپرسور: +86-18157593311

خط تلفن لوله گرمایش برقی: +86-13857577938

ایمیل: helenliu1983xtld@gmail.com

کارخانه لوله های گرمایشی برقی: شماره ۱۵۰، روستای دونگ هو، شهر گانلین، شهر شنگژو، شهر شائوشینگ

کارخانه کمپرسور: شماره ۶۷۹، منطقه توسعه اقتصادی دونگ گو، شهر شنگژو، شهر شائوشینگ

کپی رایت © ۲۰۲۶ شرکت فناوری محیط زیست ژجیانگ شیتلیدو و شرکت فناوری محیط زیست شنگچوانلی. کلیه حقوق محفوظ است.